RANCO series four-way reversal valves are applicable for hot pump systems such as central, unit and room air conditioners. The switch between cooling mode to heating mode can be realized by changing flow path of coolants.

Technical parameters

  • Features
    • Specifications: 1-240 ton (R22 nominal capacity)
    • Power saving: can be used with bi-stable coils to ensure almost zero energy consumption
    • Energy saving: stainless steel series with optimized materials, consuming 5% less energy than regular products
  • General specifications
    • Applicable refrigerant: R22, R407C and R410A etc.
    • Applicable medium temperature: -25ºC~120ºC
    • Maximum working pressure: R22: 3.0 MPa
      R407C: 3.3 MPa
      R410A: 4.2 MPa
    • Applicable ambient temperature: -25ºC~50ºC
    • Relative humidity: below 95% RH
    • Certification: UL, TUV, CQC
  • Electrical parameters of coil
    TypeClassification:Rated Voltage VFrequency HzPower W
    Coils with Lead Wires SHF-4-10W AC220V?240V?AC208V?230V?AC220V?AC115V?120V?AC100V?AC24V 50/60 4.5/3.5
    AC200V 50/60 6/5
    DC35V / 7
    SHF-4-10L AC220V?240V?AC200V?AC100V?AC110V?120V?AC24V?AC265V?277V 50/60 4.5/3.5
    Coil with Spade Connection SHF-4-10EA AC220V?240V?AC220V?AC115V?120V?AC100V?110V?AC24V?AC265V?277V?AC200V 50/60 6/5
    SHF-4-10FA AC220V?240V?AC220V?AC115V?120V?AC100V?110V?AC24V 50/60 6/5
    Coils with Lead Wires LDL-41 AC208V?240V 50/60 5/4
    LDL-31 AC120V 50/60 5/4
    LDL-11 AC24V 50/60 5/4
    LDL-51 AC277V 50/60 5/4
    Coil with Spade Connection LDK-31 AC120V 50/60 5/4
    LDK-11 AC24V 50/60 5/4
    LDK-41 AC208V?240V 50/60 5/4
    LDK-51 AC277V 50/60 5/4
  • Dimensions

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F D Tube E/S/C Tube
    C01C00S 101 40,5 50 62 102,5 42 12 8.1/8.5 9.6/10
    C02C00S 125 52 59 70 120 52,5 16 9.7/9.5 12.75/9.5
    N01C00G 104Max 42,5 50 62 104,5 42 12 8.1/8.5 9.64/9.7
    N02C00S 128Max 52 59 71,4 120 52,5 16 9.65/9.7 12.8/9.7
    V0-40605X-1XX 103Max 40,5 50 62 102,5 42 12 8.12/8.5 9.64/9.7
    V1-40606X-2XX 128Max 52 59 71,4 120 52,5 16 9.67/9.7 9.64/9.7
    V2-40806X-2XX 128Max 52 59 71,4 120 52,5 16 9.67/9.7 12.84/9.7

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C F G D Tube E/S/C Tube
    V1-40606X-1XX 128Max 49,3 59 71,4 16 37MAX 9.67/9.7 6.64/9.7
    V2-40806X-1XX 128Max 49,3 59 71,4 16 37MAX 9.67/9.7 12.84/9.7
    V6-414080-1XX 199Max 66,7 82,6 95 28,5 41MAX 12.83/12.7 22.36/22.4
    V10-418100-1XX 210.8Max 81,8 85,9 98,6 33,5 46MAX 16.03/12.7 28.78/25.4
    C05C00S 200 68 85 95 28,5 37,4 12.8/13 19.15/19
    C10C00S 217Max 82 86 99 33,5 42,7 19.2/19 22.4/22
    C15C00S 240Max 91 96 109 37 42,7 22.4/22 28.8/25.4
    N05C00S 203Max 66,7 82,6 95,3 28,6 38 12.8/13 19.2/19
    N10C00S 214Max 82 86 99 33 42,7 19.2/19 22.4/22
    N15C00G 240Max 91 96 109 37 42,7 22.4/22 28.8/25.4

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C F G D Tube E/S/C Tube
    N20C00G 337Max 111 117 131 45 78,8 25.6/25.4 32/30
    N30C00G 337Max 111 117 131 45 78,8 32/25 38.3/30
    VH1320A 337Max 111 117 131 45 78,8 25.6/25.4 32/30
    VH1322A 337Max 111 117 131 45 78,8 28.8/25.4 35.2/30
    VH15120 337Max 111 117 131 45 78,8 32/25 38.3/30

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C F G ? D Tube E/S/C Tube
    V2-410060-3XX 128Max 49,3 57,4 71,4 23,6 37Max 15 9.67/9.7 16.03/16
    C03C00S 125 49,3 60,5 71,6 25 33,8 15 12.8/10 16/16

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C F G H ? D Tube E/S/C Tube
    V3-410080-7XX 128Max 49,3 60,5 71,6 24,1 37Max 16 15 12.84/9.7 16.03/15.8
    V3-412080-8XX 128Max 49,3 82,6 87,6 32,5 37Max 16 20 12.84/9.7 19.18/19.1
    N03C00S 128Max 49,3 60,5 71,6 24,1 34 16 15 12.8/10 16/16

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C F G H D Tube E/S/C Tube
    V6-4140K0-2XX 203Max 85,9 82,6 95,3 28,5 41Max 28,5 15.82/19.05 22.36/22.4

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C F G D Tube E/S/C Tube
    V12-4220T0-2XX 268Max 96,8 149,9 175,3 41,4 46Max 28,58 35.13/25.4

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J K D Tube E/S/C Tube
    N20C10G 337Max 111 117 131 188 94 45 108 120 145 ?13 57 25.6/25.4 32/30
    N20C11G 337Max 111 117 131 188 94 45 108 120 145 ?13 57 28.8/25.4 35.2/30
    N30C10G 337Max 111 117 131 188 94 45 108 120 145 ?13 57 32/25 38.3/30
    N40C10G 422Max 135 148 168 226 113 58 112 166 200 ?13 63 38.1/33 45/40
    N40C11G 422Max 135 148 168 226 113 58 112 166 200 ?13 63 38.1/33 41.5/40
    N50C10G 422Max 135 148 198 226 113 58 112 166 200 ?13 63 38.1/33 54.2/40
    N60C10G 500Max 135 148 198 262 131 71,5 112 166 200 ?13 63 41.5/33 67/40
    VH10120 337Max 111 117 131 188 94 45 108 120 145 ?13 57 25.6/25.4 32/30
    VH10122 337Max 111 117 131 188 94 45 108 120 145 ?13 57 28.8/25.4 35.2/30
    VH15122 337Max 111 117 131 188 94 45 108 120 145 ?13 57 32/25 38.3/30
    VH20321 422Max 135 148 168 226 113 58 112 166 200 ?13 63 38.1/33 45/40
    VH20322 422Max 135 148 168 226 113 58 112 166 200 ?13 63 41.5/33 41.5/40
    VH90120 422Max 135 148 198 226 113 58 112 166 200 ?13 63 38.1/33 54.2/40
    VH90121 422Max 135 148 198 226 113 58 112 166 200 ?13 63 44.7/33 54.2/40
    VH91120 500Max 135 148 198 262 131 71,5 112 166 200 ?13 63 41.5/33 67/40

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D Tube E/S/C Tube
    VH32082 480 350 445 100 FLANG E RBK50A FLANG E RBK65A

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J D Tube E/S/C Tube
    VH32084 480 350 445 130 635 100 171 360 120 160 12×24 FLANG E RBK50A FLANG E RBK65A

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J D Tube E/S/C Tube
    VH32085 480 350 445 130 635 100 171 360 120 160 12×24 FLANG E RBK50A FLANG E RBK65A

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J K M N O D Tube E/S/C Tube
    VH32087a 422Max 514 428 365 295 172 171 270 261 17 62 13 100 95 100 54.2/40 79.38/40
    VH32108a 422Max 521 428 365 295 172 171 270 261 17 62 13 100 95 100 66.68/40 79.38/40

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J D Tube E/S/C Tube
    VH32122 480 450 635 445 130 100 171 360 120 250 12×24 FLANG E RBK50A FLANG E RBK65A

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J D Tube E/S/C Tube
    VH32123 480 450 635 445 130 100 171 360 120 250 12×24 FLANG E RBK50A FLANG E RBK65A

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J D Tube E/S/C Tube
    VH32163 480 545 635 445 130 360 171 100 120 250 12×24 FLANG E RBK50A FLANG E RBK65A

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J K D Tube E/S/C Tube
    VH32126B 428 445 528 172 270 85 171 10 95 95 100 80 79.38/40 79.38/40

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J K M D Tube E/S/C Tube
    VH32166B 428 540 528 172 270 85 171 10 95 95 95 100 80 79.38/40 79.38/40

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J K M N O P D Tube E/S/C Tube
    VH32205C 700 560 748 511 141,5 480 215 600 250 115 100 95 95 95 100 12x24 81 (FLANG) 119 (FLANG)
    VH32245C 700 560 775 515 141,5 480 226,8 600 250 115 100 95 95 95 100 12x24 106,3 (FLANG) 119 (FLANG)

     

    Ranco brand for central air conditioner

    Model Dimensions mm Connection Size/Connection Depth mm
    L A B C D E F G H I J K M D Tube E/S/C Tube
    VH32086B 422 Max 428 528 345 350 172 171 270 80 65 90 15 20 79.38/40 79.38/40